Retiring the Central Fleet Manager Without Losing the Floor
A centralized fleet manager fails like a single database: when it goes down, every robot on the floor stops, so one server and one wireless controller set the upper limit on your uptime. Decentralized consensus navigation removes that ceiling. It does not remove the cost. The cost moves into lease logic, partition handling and a safety recertification you cannot skip, and the budget only holds up if you tie each of those costs to a number you can measure before and after cutover.
What the old stack was actually buying you
A central planner sees every path at once, so it resolves deadlocks before they form and keeps aisle throughput close to optimal. Robots that negotiate space with their mesh neighbours only see a local horizon. They will sometimes yield where a global solver would have threaded them through, and on a dense layout that shows up as queueing at intersections. By our own estimate, peak throughput in narrow-aisle layouts drops 5 to 10 percent against a well-tuned central solver. Put that figure next to the production minutes you currently log against fleet manager outages and network controller failovers. If the outage minutes cost more than the throughput loss, the migration pays for itself. If they cost less, you are buying resilience you have not yet needed, and you should say so plainly in the budget review.
Leases, not locks
In the decentralized stack, each robot holds time-bounded leases on spatial cells, and a lease is granted only when a majority of the robots registered as claimants for that cell agree. When a holder goes silent because of a dead battery, a crashed process or a radio shadow, its lease simply expires and the neighbours reclaim the cell, so a central arbiter never has to notice the failure. The failure mode to design against is a mesh partition: two groups of robots on either side of a dead access point can each believe they hold a quorum, and both can book the same intersection. The defence has three layers: strict majority quorum computed against the full claimant set, a stop-and-hold default for any robot that loses contact with its majority, and the safety-rated scanners on each vehicle as the last physical barrier, which never depend on the network at all. Lease duration is the parameter that sets your recovery behaviour, and we start at 2 s: shorter leases recover faster from a dead robot but generate more radio traffic and spurious expiries under interference, while longer leases leave cells blocked by robots that are already gone. The rule we apply is to set the lease to at least three times the 99th-percentile round-trip latency measured on your worst mesh segment, and if that number exceeds the time a robot needs to cross the cell, split the cell instead of lengthening the lease.
The part that hurts
The risk assessment behind your current deployment almost certainly assumes a central traffic controller, and mobile robot safety standards such as ISO 3691-4 will force you to rewrite it even though the protective function itself stays on the vehicle. Debugging changes character too. An incident no longer lives in one log but emerges from a handful of robots disagreeing for a few hundred milliseconds, so you need distributed tracing on synchronized clocks before the first robot leaves shadow mode, not after the first collision report. Our estimate is that commissioning effort for the first site roughly doubles, and most of that time goes into reproducing emergent behaviour that never appears in simulation. The measurable trade you are buying with that effort is operator interventions per shift: track them on the old stack for a full month before cutover, because without that baseline you will not be able to prove that the pain bought anything.
Cutting over without betting the shift
Run the decentralized layer in shadow mode under the existing fleet manager, log every reservation it would have granted against the central plan, and cut over zone by zone only after the conflict count between the two reaches zero on your busiest shift, because that is the last cheap moment to find a partition bug.
Technical FAQ: Can we keep the central manager running as a fallback after cutover?
You can keep it as an observer and optimiser that suggests routes, but do not let it hold authority over space. A dual authority reintroduces exactly the split-brain conflict the lease quorum was designed to prevent, and when the central node fails you are back to the single point of failure you paid to remove.